An ELEMENT to represent the dose frequency as the number of occurrences of a periodic or recurrent process per unit time [
ePS] in terms of a measurable calendar cycle.
MeasuredDoseTiming is used to represent an interval of time that recurs periodically. The two main properties are phase and
period/frequency. phase. E.g. twice a day, twice a day for ten minutes, every September, every other Saturday, and every four
to six hours1.
1. ISO 21090 Harmonized data types for information interchange (See PIVL data type)
Specializes
Attributes
| Name |
Data type |
Occurs |
Description |
Value constraints |
| name |
SC
|
1..1 |
The name, expressed as a coded value or as plain text, specifies the clinical or administrative concept to which this EHR
node corresponds, as labelled in the EHR system in which it was first committed.
|
| value |
| Literal value(s): UNBOUND_DATA_ELEMENT |
|
| rc_id |
II.Uuid
|
1..1 |
The globally-unique identifier by which this node in the EHR hierarchy is referenced in the EHR system to which the data were
first committed. This identifier shall be retained by the EHR Recipient and re-used whenever this RECORD_COMPONENT is subsequently
included in another EHR_EXTRACT.
|
|
| synthesised |
BL
|
1..1 |
This attribute value shall be TRUE if this RECORD_COMPONENT has been created in order to comply with this standard , but this
point in the EHR hierarchy has no corresponding node in the EHR from which it was extracted.
|
| value |
| Default value: false |
|
| obs_time |
IVL_TS
|
0..1 |
The date and time, or interval, in which the unbound data applied. |
|
| value |
ANY
|
1..1 |
Represents the unbound data. |
|
Component Relationships
Object Relationships
Item of ENTRY Constrained Domain Models
Reference Model Type