Logical Record Architecture for Health and Social Care

Discharge Summary Release 0.02

The content of this release is not comprehensive and is not fully validated and must not be used in live system implementations.

ELEMENT Domain Model: GenericSpecimen

An ELEMENT to represent a specimen entity.

Attributes

Name Data type Occurs Description Value Constraints
name SC 1..1 The name, expressed as a coded value or as plain text, specifies the clinical or administrative concept to which this EHR node corresponds, as labelled in the EHR system in which it was first committed.
rc_id II 1..1 The globally-unique identifier by which this node in the EHR hierarchy is referenced in the EHR system to which the data were first committed. This identifier shall be retained by the EHR Recipient and re-used whenever this RECORD_COMPONENT is subsequently included in another EHR_EXTRACT.
meaning CD.CV.SCT 1..1 A coded representation of the specimen.

code
Semantic expression constraint
synthesised BL 1..1 This attribute value shall be TRUE if this RECORD_COMPONENT has been created in order to comply with this standard, but this point in the EHR hierarchy has no corresponding node in the EHR from which it was extracted. Within the LRA this attribute is used to indicate a RECORD_COMPONENT instance that has been derived in some way from a pre-existing RECORD_COMPONENT.
value QTY 1..1 The value attribute shall carry a null flavor of Not Applicable (NA).

nullFlavor
Literal value(s): NA


COMPONENT RELATIONSHIPS

Subject of relationships

Name Object of relationship Occurs Dependency
IsProductOf SpecimenCollection 0..* INDEPENDENT


Object of relationships

Name Subject of relationship Occurs Dependency
HasSpecimen GenericInvestigation 0..* INDEPENDENT

Item of ENTRY Domain Models

Kt/V

UreaReductionRatio

Reference Model Type

MATERIAL_ENTITY_ELEMENT