An ELEMENT to represent the observation of a patient's oxygen saturation level
Attributes
| Name |
Data type |
Occurs |
Description |
Value Constraints |
|
name
|
SC
|
1..1 |
The name, expressed as a coded value or as plain text, specifies the clinical or administrative concept to which this EHR
node corresponds, as labelled in the EHR system in which it was first committed.
|
| value |
| Literal value(s): PROPERTY_OBSERVATION_ELEMENT |
|
|
archetype_id
|
ST
|
0..1 |
The unique identifier of the archetype node to which this RECORD_COMPONENT corresponds, either in the EHR Provider system
or as a mapping produced when this EHR_EXTRACT was created. The syntax for populating this attribute value is defined in EN
13606-2:2008.
Within the LRA the value assigned to this attribute SHALL have no effect on the interpretation of instances of this class
and the attribute SHALL not be used as a predicate for semantic data retrieval.
|
|
|
rc_id
|
II
|
1..1 |
The globally-unique identifier by which this node in the EHR hierarchy is referenced in the EHR system to which the data were
first committed. This identifier shall be retained by the EHR Recipient and re-used whenever this RECORD_COMPONENT is subsequently
included in another EHR_EXTRACT.
|
|
|
meaning
|
CD.CV.SCT
|
1..1 |
The standardised clinical or administrative concept to which the name attribute has been mapped. In archetyped systems it
will correspond to the archetype node name. In non-archetyped systems it might be a coded term from an appropriate terminology
system.
|
|
|
synthesised
|
BL
|
1..1 |
This attribute value shall be TRUE if this RECORD_COMPONENT has been created in order to comply with this standard , but this
point in the EHR hierarchy has no corresponding node in the EHR from which it was extracted.
|
| value |
| Default value: false |
|
|
policy_ids
|
II
|
0..1 |
This attribute identifies one or more access control policies that specifically pertain to this RECORD_COMPONENT and which
need to be communicated to the EHR Recipient to govern future access to it. The identifiers may refer to policy information
included in this EHR_EXTRACT as defined in EN 13606-4:2007, or to policies held in external policy servers to which the EHR
Recipient has access.
|
|
|
sensitivity
|
INT
|
0..1 |
The sensitivity of this RECORD_COMPONENT, represented using the code set for this attribute defined in EN 13606-4:2007. |
|
|
orig_parent_ref
|
II
|
0..1 |
The identity of the RECORD_COMPONENT that is the original parent (context) for this RECORD_COMPONENT, to be present if this
information has been copied from another part of the EHR of this subject of care..
|
|
|
obs_time
|
IVL_TS
|
0..1 |
The date and time, or interval, at which the ITEM actually occurred or was true, if different from the session time of the
COMPOSITION.
|
|
|
value
|
PQ
|
1..1 |
Oxygen saturation is measured as a percentage
|
|
COMPONENT RELATIONSHIPS
Object of relationships
Item of ENTRY Domain Models
Reference Model Type