Logical Record Architecture for Health and Social Care

Discharge Summary Release 0.02

The content of this release is not comprehensive and is not fully validated and must not be used in live system implementations.

ELEMENT Domain Model: FluidIntakeRateObservation

An ELEMENT to represent the result of a fluid intake rate measurement. Fluid intake rate shall be measured in millilitres per day.

Attributes

Name Data type Occurs Description Value Constraints
name SC 1..1 The name, expressed as a coded value or as plain text, specifies the clinical or administrative concept to which this EHR node corresponds, as labelled in the EHR system in which it was first committed.

value
Literal value(s): PROPERTY_OBSERVATION_ELEMENT
rc_id II 1..1 The globally-unique identifier by which this node in the EHR hierarchy is referenced in the EHR system to which the data were first committed. This identifier shall be retained by the EHR Recipient and re-used whenever this RECORD_COMPONENT is subsequently included in another EHR_EXTRACT.
meaning CD.CV.SCT 1..1 A coded representation of the fluid intake rate observation.

code
Semantic expression constraint
synthesised BL 1..1 This attribute value shall be TRUE if this RECORD_COMPONENT has been created in order to comply with this standard , but this point in the EHR hierarchy has no corresponding node in the EHR from which it was extracted.

value
Default value: false
obs_time IVL_TS 0..1 The date and time of the fluid intake rate observation.
value IVL_PQ 1..1 The value of the fluid intake rate observation. Fluid intake rate shall be measured as a ratio of physical quantities; the numerator shall be measured in millilitres and the denominator shall be measured in days (e.g. 2000 millilitres per day).

unit
Literal value(s): mL/d


COMPONENT RELATIONSHIPS

Object of relationships

Name Subject of relationship Occurs Dependency

Item of ENTRY Domain Models

FluidIntakeRate

Diagnosis

Reference Model Type

PROPERTY_OBSERVATION_ELEMENT