An ELEMENT to represent an Interpretation Range against which an observation was/may be interpreted. This is generally a Reference
Range but may also be a Reference Change Value (RCV)1.
1: NPFIT-FNT-TO-DPM-0725.06 - NPfIT Message Implementation Manual 7.2.02
Attributes
| Name |
Data type |
Occurs |
Description |
Value Constraints |
|
name
|
SC
|
1..1 |
The name, expressed as a coded value or as plain text, specifies the clinical or administrative concept to which this EHR
node corresponds, as labelled in the EHR system in which it was first committed.
|
| value |
| Literal value(s): UNBOUND_DATA_ELEMENT |
|
|
rc_id
|
II
|
1..1 |
The globally-unique identifier by which this node in the EHR hierarchy is referenced in the EHR system to which the data were
first committed. This identifier shall be retained by the EHR Recipient and re-used whenever this RECORD_COMPONENT is subsequently
included in another EHR_EXTRACT.
|
|
|
synthesised
|
BL
|
1..1 |
This attribute value shall be TRUE if this RECORD_COMPONENT has been created in order to comply with this standard , but this
point in the EHR hierarchy has no corresponding node in the EHR from which it was extracted.
|
|
|
obs_time
|
IVL_TS
|
0..1 |
The date and time, or interval, in which the interpretation range applied. |
|
|
value
|
IVL_PQ
|
1..1 |
Represents the actual value(s) of the interpretation range that have been used for interpretation of the Observation. |
|
COMPONENT RELATIONSHIPS
Subject of relationships
Object of relationships
Item of ENTRY Domain Models
Reference Model Type