ITK Implementation
Trigger Events
Interactions
Child Screening Report interactions
Note : A Business Acknowledgement is only returned on receipt of a message where the received Distribution Envelope has a handlingSpecification with a key of “urn:nhs-itk:ns:201005:ackrequested” and a value of “true”.
| Primary Recipient Child Screening Report (urn:nhs-itk:interaction:primaryRecipientChildScreeningReport-v1-0)
Communicates a Child Screening Report to a primary recipient where the recipient is recommended to act upon information carried in the document. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: Child Screening Report Originating System (POCD_AR010001GB01) Receiver: Child Screening Report Primary Receiving System (POCD_AR010002GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: SendCDADocument-v2-0 CoreServices-v1-0.wsdl |
| Copy Recipient Child Screening Report (urn:nhs-itk:interaction:copyRecipientChildScreeningReport-v1-0)
Communicates a Child Screening Report to a copy recipient where the document is for information only and NO system action is defined. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: Child Screening Report Originating System (POCD_AR010001GB01) Receiver: Child Screening Report Copy Recipient (POCD_AR010003GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: SendCDADocument-v2-0 CoreServices-v1-0.wsdl |
| Nullify Child Screening Report (urn:nhs-itk:interaction:nullifyChildScreeningReport-v1-0)
Communicates the nullification (by replacement) of any Child Screening Report sent to any recipient. Must be sent to all information recipients (including copy recipients). Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: Child Screening Report Originating System (POCD_AR010001GB01) Receiver: Child Screening Report Primary Receiving System (POCD_AR010002GB01) Receiver: Child Screening Report Copy Recipient (POCD_AR010003GB01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: SendCDADocument-v2-0 CoreServices-v1-0.wsdl |