ITK Implementation
Trigger Events
Interactions
Ambulance Report interactions
Note : Message acknowledgements and responses are requested by the document sender via handlingSpecifications within the ITK Distribution Envelope. For more detail on handlingSpecifications and the acknowledgement framework see the ITK Core pack (available from TRUD).
| handlingSpecification key | handlingSpecification allowable values |
|---|---|
| urn:nhs-itk:ns:201005:infackrequested | “true” or “false” |
| urn:nhs-itk:ns:201005:ackrequested | “true” or “false” |
| urn:nhs-itk:ns:201005:busresponserequested | “false” |
| Primary Recipient Ambulance Service Patient Report (urn:nhs-itk:interaction:primaryRecipientAmbulanceServicePatientReport-v1-0)
Communicates an Ambulance Service Patient Report to a primary recipient where the recipient is recommended to act upon information carried in the document. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: Ambulance Service Patient Report Originating System (POCD_AR030001UK01) Receiver: Ambulance Service Patient Report Primary Receiving System (POCD_AR030002UK01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: SendCDADocument-v2-0 CoreServices-v1-0.wsdl |
| Copy Ambulance Service Patient Report: (urn:nhs-itk:interaction:copyRecipientAmbulanceServicePatientReport-v1-0)
Communicates an Ambulance Service Patient Report to a copy recipient where the document is for information only and NO system action is defined. Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: Ambulance Service Patient Report Originating System (POCD_AR030001UK01) Receiver: Ambulance Service Patient Report Copy Recipient (POCD_AR030004UK01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: SendCDADocument-v2-0 CoreServices-v1-0.wsdl |
| Nullify Ambulance Service Patient Report (urn:nhs-itk:interaction:nullifyAmbulanceServicePatientReport-v1-0)
Communicates the nullification (by replacement) of any Ambulance Service Patient Report sent to any recipient. Must be sent to all information recipients (including copy recipients). Note: This interaction has a message format that is constrained using HSCIC templates. This format is validated using a two level process. There are two sets of schema one for each level. The sender of this interaction must build all instances to the "on the wire" format using the generic CDA definition indicated in the wire format below. These instances must also conform to the rules stated in the conformance definition indicated in the conformance format below. The second level of validation requires transformation before schema validation can take place. For full details of this validation process please see the "Technical Guidance for Templated CDA Domains" section under the associated specifications tab. Sender: Ambulance Service Patient Report Originating System (POCD_AR030001UK01) Receiver: Ambulance Service Patient Report Primary Receiving System (POCD_AR030002UK01) Receiver: Ambulance Service Patient Report Copy Recipient (POCD_AR030004UK01) Message:
Transmission Wrapper: ITK Distribution Envelope (Version 2.0) (distributionEnvelope-v2-0) Web Service Wrapper: SendCDADocument-v2-0 CoreServices-v1-0.wsdl |
